Automatic Potentiometric Titrator AT-710 M
Kem AT-710 M potentiometric titrator with touch panel operation and color screen with online graphical display of titration processes.
Highly expandable, four connectable titration units: Karl Fischer Volumetric, Coulometric (MKV-710 B and MKC-710 B), and Potentiometric (AT-710 B).
Display and keyboard features: 8.4-inch, color, 800 x 600-dot LCD screen, connection of up to four titration units that can be displayed individually or simultaneously.
Possible titration processes: acid-base, redox, argentometric – ppt (electrodes to be ordered separately); with an additional preamplifier, complexometric, photometric, conductometric, and polarized current titrations can be performed.
Titration modes: EP (automatic search for equivalent point(s), LEVEL STOP (End point), FULL (maximum number of points, stop at volume), Specific programs for petroleum products (TAN, TBN). Special functions: pKa (acid dissociation constant), potential measurements (pH or mV).
Additions during titrations: AUTO TITRATION (automatic increase/decrease of added volume based on the first derivative), AUTO INTERMIT (constant additions upon reaching constant potential), INTERMIT (fixed additions at pre-set time intervals), STAT (maintain constant pH value). INTERCEPT, EP + LEVEL STOP.
Calculations: Concentration, processed data statistics (mean, SD, and RSD), storage and averaging of titrant reagent factors, storage and averaging of blanks, ability to express concentration in 5 different units for each analysis, recalculation of stored values.
Internal memory: for 120 methods, 10 combined methods + 2 “link” methods, 500 results. pH calibration: maximum 3 points, user-selectable or predefined buffers (NIST, DIN, ASTM, etc.).
Interchangeable burette equipped with an IC chip to store titrant information: 20 ml, mounted on a 20,000-step stepper motor (accuracy +- 0.01 ml), other optional volumes: 1, 5, 10, and 50 ml. Possibility of mounting up to 2 integrated burettes and connecting up to 8 additional external ones for dispensing titrants or auxiliary reagents.
Connections: SS BUS for CHA-700 autosampler (6 or 11 positions) and external burette motors, RS 232C (2) for printer, PC, balance, USB for data download (PDF) via USB stick / connection to external alphanumeric keyboard / barcode reader, ELE for “smart” electrode (memorizes calibration), TEMP. COMP: Pt100 terminal to correct the titrant volume dispensed based on reagent temperature.
GLP compliance: date and time, method, operator name, electrode calibration record, etc. (GLP report configurable for printing), user access via password.
Dimensions and weight: Titration unit / printer WxDxH (mm): 141x296x367 (without tubes) / 106x180x88, weight 4 kg. Screen WxDxH (mm): 225x190x42.
Permissible ambient conditions: 5-35°C, maximum 85% relative humidity (non-condensing).
Power supply: AC 100-240 V +/- 10%, 50/60 Hz.
Standard equipment: depending on configuration.
CE certification. EMC: EN61326-1 LVD: EN61010-1 RE: directive. Burettes EBU: FCC Part 15 Subpart C FCC ID: 2ABSVEBU01.

Automatic Potentiometric Titrator AT-710 S
Kem AT-710 S potentiometric titrator with “Touch Panel” operation, color screen with online graphic display of titration processes.
Display and keyboard features: 8.4-inch color LCD screen, 800 x 600 dots, single titration channel display.
Possible titration processes: acid-base, redox, argentometric – ppt (electrodes must be ordered separately); with an additional preamplifier, complexometric, photometric, conductometric, and polarized current titrations can be performed.
Titration modes: EP (automatic search for equivalent point(s), LEVEL STOP (end point), FULL (maximum number of points, stop at volume), petroleum product-specific programs (TAN, TBN). Special functions: pKa (acid dissociation constant), potential measurements (pH or mV).
Additions during titrations: AUTO TITRATION (automatically increases/decreases added volume based on the first derivative), AUTO INTERMIT (constant additions upon reaching a constant potential), INTERMIT (fixed additions at predetermined time intervals),
STAT (maintains a constant pH value). INTERCEPT, EP + LEVEL STOP.
Calculations: concentration, processed data statistics (mean, SD, and RSD), storage and averaging of titrant reagent factors, storage and averaging of blanks, ability to express concentration in 5 different units for each analysis, recalculation of stored values.
Internal memory: for 120 methods, 10 combined methods + 2 “link” methods, 500 results. pH calibration: maximum 3 points, user-selectable or predefined buffers (NIST, DIN, ASTM, etc.).
Interchangeable burette equipped with an IC chip to store titrant information: 20 ml, mounted on a 20,000-step stepper motor (accuracy +- 0.01 ml), other optional volumes: 1, 5, 10, and 50 ml. Possibility of mounting up to 2 integrated burettes and connecting up to 8 additional external ones for dispensing titrants or auxiliary reagents.
Connections: SS BUS for CHA-700 autosampler (6 or 11 positions) and external burette motors, RS 232C (2) for printer, PC, balance, USB for data download (PDF) via USB stick / connection to external alphanumeric keyboard / barcode reader, ELE for “smart” electrode (memorizes calibration), TEMP. COMP: Pt100 terminal to correct the titrant volume dispensed based on reagent temperature.
GLP compliance: date and time, method, operator name, electrode calibration record, etc. (GLP report configurable for printing), user access via password.
Dimensions and weight: Titration unit / printer WxDxH (mm): 141x296x367 (without tubes) / 106x180x88, weight 4 kg. Screen WxDxH (mm): 225x190x42.
Permissible ambient conditions: 5…35°C, maximum 85% relative humidity (non-condensing).
Power supply: AC 100…240 V +/- 10%, 50/60 Hz.
Basic equipment: Depending on configuration.
CE certification. EMC: EN61326-1 LVD: EN61010-1 RE: directive. Burettes EBU: FCC Part 15 Subpart C FCC ID: 2ABSVEBU01.

Automatic Potentiometric Titrator AT-710 B
Kem AT-710 B “Base” potentiometric titrator, backlit LCD display.
Display and keyboard features: Backlit LCD (black and white), 7 lines x 40 characters, alphanumeric keyboard, display of one titration channel. Can be connected as an additional workstation for potentiometric titrations to the “M” series Potentiometric or Karl Fischer titrators.
Possible titration processes: acid-base, redox, argentometric – ppt (electrodes to be ordered separately); with an additional preamplifier, complexometric, photometric, conductometric, and polarized current titrations can be performed.
Titration modes: EP (automatic search for equivalent point(s), LEVEL STOP (end point), FULL (maximum number of points, stop at volume), Special functions: pKa (acid dissociation constant), potential measurements (pH or mV).
Additions during titrations: AUTO TITRATION (automatically increases/decreases added volume based on the first derivative), AUTO INTERMIT (constant additions upon reaching a constant potential), INTERMIT (fixed additions at predetermined time intervals),
STAT (maintains a constant pH value). Calculations: concentration, processed data statistics (mean, SD, and RSD), storage and averaging of titrating reactive factors, storage and averaging of blanks, ability to express concentration in 5 different units for each analysis, recalculation of stored values.
Internal memory: for 20 methods + 2 “link” methods and 50 results. pH calibration: maximum 3 points, user-selectable or predefined buffers (NIST, DIN, ASTM, etc.).
Interchangeable burette: 20 ml, mounted on a 20,000-step stepper motor (accuracy +- 0.01 ml), other optional volumes (1, 5, 10, and 50 ml). Possibility of installing up to 2 integrated burettes and connecting up to 8 external ones for dispensing titrants or auxiliary reagents.
Connections: SS BUS for CHA 700 autosampler (6 or 11 positions) and external burette motors, RS 232C (2) for printer, PC, balance, USB for data download (PDF) via USB stick / connection to external alphanumeric keyboard / barcode reader, ELE for “intelligent” electrode (memorizes calibration), TEMP. COMP: Pt100 terminal for correcting the titrant volume dispensed based on reagent temperature.
GLP compliance: date and time, method, operator name, electrode calibration record, etc. (GLP report configurable for printing).
Dimensions and weight: Titration unit / printer WxDxH (mm): 141x296x367 (without tubes) / 106x180x88, weight 4 kg.
Permitted ambient conditions: 5…35°C, maximum 85% relative humidity (non-condensing).
Power supply: AC 100…240 V +/- 10%, 50/60 Hz.
Basic equipment: depending on configuration.
CE certification. EMC: EN61326-1 LVD: EN61010-1 RE: directive. Burettes EBU: FCC part 15 Subpart C FCC ID: 2ABSVEBU01.

Accessories for printing and data recording
The 710 series titrators are expandable with a large number of accessories: 40-column or A4 format printer, software, barcode reader, etc.
IDP-100-12
Impact printer
For printing analytical reports. Features: 40 columns, plain paper. Standard accessories: 220 V power supply, cable for connecting to KEM titrators, ribbon, and 1 roll of paper.

Soft CAPE
Impact printer
Software (data saving directly to PC)
Compatible with Windows® 98SE/ME/NT/2000/XP. Connect KEM instruments to a PC and quickly and easily save analytical data in Excel format. Up to 4 KEM instruments can be connected.

CHA-700 Autosampler
Compact autosampler CHA-700/6 (6 positions) and CHA-700/11 (11 positions)
The CHA-700 autosampler is extremely compact. Unique in its kind, it was designed to be installed beneath the AT-700 titration unit, saving valuable space on the lab bench or under a hood. Simple and cost-effective, the CHA-700 offers important features such as the ability to continuously load samples into any position on the sample holder, without interrupting the analysis sequence (e.g., samples arriving at different times or urgent analyses). The analytical sequence can also include the execution of different programs on the samples being analyzed, at the operator’s discretion.
Identification data for preloaded or “on-the-fly” loaded samples, as well as variable data such as weight, volume, etc., can be entered at any time, even during the analysis, without interrupting the analytical cycle.
The supplied stirrer is a mechanical stirring rod. Washing between samples takes place in a dedicated washing vessel (immersion).
| Specifications | CHA-700 / 6 positions | CHA-700 / 11 positions |
| N° positions | 6 job + 1 washing | 11 job + 1 washing |
| Vasi standard | disposable jars 200ml, beaker 250ml or 200ml Optional: disposable jars 100ml, beaker 50ml beaker 100ml o beaker alti 100ml | disposable jars or beakers 100ml |
| Power | AC100-240V±10% 50/60Hz | AC100-240V±10% 50/60Hz |
| Absorption | Appross. 20W | Appross. 20W |
| Dimensions | 365 (W) x 443 (D) x 315 (H)mm | 365 (W) x 443 (D) x 315 (H)mm |
| Weight | Appross. 8kg | Appross. 8kg |

CHA-600 Autosampler/h2>Compact autosampler CHA-600/12 (12 positions) and CHA-600/18 (18 positions)
The CHA-600 autosampler is highly efficient and features a shower washing system to ensure cleanliness when analyzing samples that leave difficult-to-remove residues on the sensors (e.g., precipitation titrations) or when cross-contamination needs to be eliminated. The shower washing is performed by a pump, and water or suitable solvents can be used for cleaning. Washing takes place in a container located outside the sample holder, which is automatically emptied after each wash using a second pump (drain). The water or washing solvent is aspirated and discharged into special containers via tubes.
The CHA-600 offers the ability to continuously load samples into any position on the sample holder, without having to interrupt the sequence being analyzed (a very useful option when the samples to be analyzed do not all arrive at the same time but at different times, or for the analysis of “urgent” samples).
The analytical sequence can include the execution of different programs on the samples being tested, at the operator’s discretion.
The identification data for preloaded or “on-the-fly” loaded samples, as well as variable data such as weight, volume, etc., can be entered at any time, even during the analysis, without interrupting the analytical cycle.
The supplied stirrer is magnetic. A mechanical stirring rod is optional.
It is supplied complete with all accessories for proper operation (excluding vessels) and for connection to the AT-710 M or S titrant unit.
| Specifications | CHA-600 / 12 positions | CHA-600 / 18 positions |
| N° position | 12 | 18 |
| Standard vases | vasi monouso 200ml, beaker 250ml o 200ml Opzionali: vasi monouso 100ml, beaker 50ml beaker 100ml o beaker alti 100ml | vasi monouso o beaker 100ml |
| Supply | AC100-240V±10% 50/60Hz | AC100-240V±10% 50/60Hz |
| Absorption | Appross. 50W | Appross. 50W |
| Dimensions | 520 (W) x 426 (D) x 369 (H)mm | 520 (W) x 426 (D) x 369 (H)mm |
| Weight | Appross. 17kg | Appross. 17kg |